Our D-PEXE-IN-A-00 study materials are the accumulation of professional knowledge worthy practicing and remembering. There are so many specialists who join together and contribute to the success of our D-PEXE-IN-A-00 guide quiz just for your needs. As well as responsible and patient staff who has being trained strictly before get down to business and interact with customers on our D-PEXE-IN-A-00 Exam Questions. You can contact with our service, and they will give you the most professional guide.

EMC D-PEXE-IN-A-00 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Connecting power and network cables: This domain covers connecting the server to a power source with the appropriate cable and voltage, and connecting it to the network using compatible cables.
Topic 2
  • Putting the server into the rack: This section of the exam includes securely mounting the server in a compatible rack, ensuring proper airflow and cable management.
Topic 3
  • Unpacking the server: This section of the exam covers safely removing the server from its packaging, inspecting for damage, and identifying all included components.
Topic 4
  • Pre-installation tasks: This section involves preparing the environment and server for installation, including reviewing documentation, gathering tools, and verifying the proper workspace.

>> D-PEXE-IN-A-00 Exam Demo <<

D-PEXE-IN-A-00 Reliable Exam Testking | Reliable D-PEXE-IN-A-00 Test Tutorial

The price for D-PEXE-IN-A-00 study materials is quite reasonable, and no matter you are a student or you are an employee, you can afford the expense. Besides, D-PEXE-IN-A-00 exam materials are compiled by skilled professionals, therefore quality can be guaranteed. D-PEXE-IN-A-00 Study Materials cover most knowledge points for the exam, and you can learn lots of professional knowledge in the process of trainning. We provide you with free update for 365 days after purchasing D-PEXE-IN-A-00 exam dumps from us.

EMC Dell PowerEdge XE9680 and XE8640 Install Sample Questions (Q11-Q16):

NEW QUESTION # 11
A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed.
They need to update the drivers on the server.
What is a consideration before updating the driver?

  • A. You can upload the driver package using the iDRAC UI.
  • B. A single graphics driver supports all modern GPUs.
  • C. The driver package only supports Windows operating systems.
  • D. Each GPU model has a distinct driver package.

Answer: D

Explanation:
* Understanding GPU Drivers:
* Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.
* Driver Packages for Different GPU Models:
* For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.
* Importance of Model-Specific Drivers:
* Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.
* Steps to Update Drivers on Linux:
* Identify the GPU models installed in the server. This can be done using commands likelspci | grep
-i vgaor similar tools that list the hardware components.
* Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.
* Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.
* Using iDRAC for Driver Updates:
* While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported.
Drivers are usually installed within the operating system environment.
* Compatibility with Linux:
* Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.
* Reference to Official Documentation:
* Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.
* NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.


NEW QUESTION # 12
A deployment engineer is connecting the network cables on an XE9680 server. The data center administrator wants to know why the server does not have an OCP card for network connectivity.
How should the engineer respond to the administrator's query?

  • A. An OCP card is required for the server to achieve POST when powered on.
  • B. The OCP card is an optional component.
  • C. The server does not support an OCP card.
  • D. The LOM card acts as an OCP card and supports OCP 3.0.

Answer: B

Explanation:
* Overview of OCP Cards:
* Open Compute Project (OCP) cards are network interface cards designed to provide high-speed networking capabilities. They are often used in data center environments to enhance network performance and flexibility.
* OCP Card on Dell PowerEdge XE9680:
* For the Dell PowerEdge XE9680 server, an OCP card is not a mandatory component. The server can achieve Power-On Self-Test (POST) and function normally without an OCP card.
* Optional Component:
* The OCP card is considered an optional component for the XE9680 server. This means it can be added based on specific networking needs but is not essential for the server's basic operations.
* Networking Alternatives:
* The XE9680 server is equipped with various other network interface options. For instance, it has integrated network ports (LAN on Motherboard, or LOM) which provide necessary network connectivity out-of-the-box.
* Customization and Upgrades:
* The optional nature of the OCP card allows data center administrators to customize their servers based on their network performance requirements. If high-speed or specific networking features are needed, the OCP card can be added accordingly.
* Communicating with the Administrator:
* The deployment engineer should explain to the data center administrator that while the OCP card is not included by default, it can be added as per the data center's specific networking needs. The server's design supports flexibility in network configurations.
References:
* Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed information on the components and optional upgrades available for the XE9680 server.
* Dell EMC Networking Guide: This guide outlines various networking options and configurations available for Dell PowerEdge servers, including the role and installation of OCP cards.


NEW QUESTION # 13
A deployment engineer arrives on-site to install an XE9680 server. The server lift does not have the ability to maneuver beneath the XE9680 shipping pallet.
How many people must you have to physically pick up the server to place it on the lift shelf?

  • A. 2. At least one person on each side is needed to pick up the server and place on the lift.
  • B. 4. The server is heavy, and the lift shelf does not rest on the floor.
  • C. 3. Two people are needed to tilt the server while the third person slides the shelf beneath the server.
  • D. 1. They can tilt the server and slide the lift underneath.

Answer: B

Explanation:
* Weight and Size of the PowerEdge XE9680:
* The Dell PowerEdge XE9680 server is designed for high performance, which often results in a larger and heavier form factor. Handling such servers typically requires multiple people to ensure safety and prevent damage.
* Ergonomic Considerations:
* Due to its weight and size, it is crucial to follow proper ergonomic practices when lifting and moving the server. This minimizes the risk of injury and ensures the server is handled safely.
* Number of People Required:
* For the XE9680, it is recommended to have four people when physically picking up the server to place it on the lift shelf. This recommendation is based on the server's weight and the need to maneuver it safely onto the lift.
* Safety and Coordination:
* Each person should position themselves on one side of the server, ensuring an even distribution of weight. This coordinated effort helps in lifting the server evenly and reducing the risk of dropping or mishandling it.
* Procedure for Lifting:
* Two individuals should position themselves at the front corners, and two at the rear corners of the server. On a coordinated count, all four should lift the server together and place it gently onto the lift shelf.
* The lift shelf should be stable and able to support the weight of the server once it is placed on it.
* Using the Lift:
* Once the server is on the lift shelf, it can be maneuvered into the desired position in the rack.
Ensure that the lift is rated for the weight of the XE9680 to avoid any mechanical failures.
* Reference to Official Documentation:
* Dell's installation guides and service manuals typically provide guidelines on the number of personnel required for handling large and heavy servers, ensuring both safety and compliance with best practices.
References:
* Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed guidelines on handling and installing the XE9680 server, including the recommended number of personnel required for safe handling.
* Dell EMC Technical Specifications Guide: Offers insights into the physical dimensions and weight of the PowerEdge XE9680, informing the need for multiple personnel for safe handling and installation.


NEW QUESTION # 14
A customer wants to implement 20 PowerEdge XE9680 servers for development and rendering of their studio CGI production. The solution includes a shared development environment with multiple outside partners, professionals, and hobbyists.
Due to the heating and cooling limitations of the data center, what GPUs should be used for the servers?

  • A. AMD ROCm
  • B. NVIDIA H100 GPUs
  • C. NVIDIA A100 GPUs
  • D. Intel Data Center Max 1550

Answer: C

Explanation:
For a customer implementing PowerEdge XE9680 servers in a data center with heating and cooling limitations, the NVIDIA A100 GPUs are a suitable choice. Here's a detailed explanation:
* GPU Efficiency: The NVIDIA A100 GPUs are known for their energy efficiency, which is crucial in environments with heating and cooling constraints1.
* Performance: These GPUs provide excellent performance for CGI production, supporting complex rendering tasks1.
* Compatibility: The PowerEdge XE9680 supports a range of powerful GPUs, including the NVIDIA A100, which is designed for AI, machine learning, and high-performance computing tasks1.
* Cooling Requirements: The NVIDIA A100 GPUs have a lower thermal design power (TDP) compared to the NVIDIA H100 GPUs, making them more suitable for data centers with limited cooling capabilities1.
By choosing NVIDIA A100 GPUs, the customer can ensure that their PowerEdge XE9680 servers will deliver the required performance for CGI production while adhering to the data center's heating and cooling limitations.


NEW QUESTION # 15
A deployment engineer is preparing to install three PowerEdge XE9680 servers in a rack supplied by the customer.
What must they before going on-site to install the servers?

  • A. The customer completed the required training on the server.
  • B. The rack can accommodate the length of the servers.
  • C. The rack has at least six PDUs and two power sources.
  • D. The rack will have a top-of-rack switch.

Answer: B

Explanation:
* Server Dimensions and Rack Compatibility:
* The Dell PowerEdge XE9680 is a large server with specific dimensional requirements. Ensuring that the customer's rack can accommodate the physical length and depth of the server is crucial for a successful installation.
* Rack Depth and Space Requirements:
* Measure the depth of the customer's rack to ensure it is sufficient to house the XE9680 servers.
The server's dimensions, including its length, should be verified against the available space in the rack.
* Server Length Specification:
* The PowerEdge XE9680 has a significant depth, typically around 800mm (31.5 inches). The rack must be deep enough to support the full length of the server, including any cable management and airflow requirements.
* Checking Rack Specifications:
* Verify that the rack adheres to standard dimensions suitable for hosting enterprise-grade servers.
Ensure that the rack has appropriate mounting options, such as square or threaded holes compatible with the server's rail kit.
* Pre-installation Verification:
* Before arriving on-site, confirm with the customer that their rack meets the necessary specifications. This includes checking for sufficient clearance at the rear for cable connections and at the front for proper airflow.
* Importance of Proper Fit:
* A rack that cannot accommodate the length of the servers will result in installation failure, potential damage to the hardware, and inefficient cooling. It may also pose safety risks during and after installation.
* References and Documentation:
* The Dell EMC PowerEdge XE9680 Installation and Service Manual provides detailed information on the server's dimensions and the necessary rack specifications. This manual should be consulted to ensure all pre-installation requirements are met.
References:
* Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides comprehensive guidelines on the server's physical dimensions and the necessary rack specifications for proper installation.
* Dell EMC Technical Specifications Guide: Offers detailed specifications and requirements for rack compatibility and server installation procedures.


NEW QUESTION # 16
......

Our D-PEXE-IN-A-00 learning questions have its own advantage. In order to make sure you have answered all questions, we have answer list to help you check. Then you can choose the end button to finish your exercises of the D-PEXE-IN-A-00 study guide. The calculation system of our D-PEXE-IN-A-00 Real Exam will start to work and finish grading your practices. Quickly, the scores will display on the screen. The results are accurate. You need to concentrate on memorizing the wrong questions.